Interior High Finish 5

Interior High Finish 5

Product Description

  • Acrylic intermediate- and finish paint with a smooth, supple consistency and good coalescence.
  • Recommended for subjects where there are aesthetic and medium functional requirements.

Unique Features

  • Good coalescence
  • Intermediate- and finish paint
  • Matt surface

Environmental Information

Protection equipment for: Spray painting: painting suit, full face mask with combined filter. Painting: eye protection, gloves. Sanding: respiratory protection.
Environment information: Clean off the paint from tools and wash them with water. Bring remains of fluent paint to the local recycling centre. Minimize your paint waste by pre-estimating how much paint you need. Keep the leftover paint for future use so you can effectively reduce the environmental impact.

Usage

  • Wooden ceilings and wooden panels or as undercoating paint on previously treated wood and iron and metal with anti-corrosion protection.
Nominal spreading rate (m2/l)
8

Preparation

Substrate
Must be primed, clean, dry, solid and suitable for paint treatment.

Treatment

  • Remove loose material and paint by cleaning and sanding.
  • Remove dirt, filth, grease and chalking material with Fluren 37.
  • Water-soluble discolouration, nicotine and soot can be cleaned with Fluren 49 and treated with Iso Primer.
  • Hard, smooth substrates must be sanded matt and primed if needed with Fix Primer.
  • Cracks, unevenness and holes must be filled.
  • New or bare cleaned wood must be primed with Stop Primer.
  • Apply 1-2 coats. Some colours require additional treatments.
Washability

Application

  • Brush, roller or spray
  • Choose appropriate tools for the desired finish
  • Apply wet-on-wet, and finish by brushing/rolling in the same direction
  • Always use the same batch number for continuous/unbroken surfaces
  • Differences in surface texture may result in shade deviations
  • Cold or heat can affect the material’s viscosity
  • Material temperature when spraying must be min. 12 °C.
  • Condensation must not form during drying/curing
  • Cold weather and high atmospheric humidity extend the drying time, complete curing and re-coat interval
  • High temperature and low atmospheric humidity reduce the drying time and complete curing
  • Always apply test treatments to check and accept the adhesion and results

Finishing

Finishing

Dry to touch at 20°C, 60% RF (Hours)
1
Recoatable at 20c, 60% RF (Hours)
8
Fully cured at 20c, 60% RF (Days)
28

Storage
Cool, frost-free and tightly closed

Cleaning of Tools etc.
Water and soap

Technical Data

Density (kg/liter)
1.38
Total emission
18 Emission cf. EN16000-9:2006 (< µg/m²h after 28 days)
Dilution
Water. When spraying, do not dilute.
Humidity
Max. humidity 80 % RH.

Version

19-11-2019